https://www.globaltechnology2814.com
917780517507

House, Delicate, Generator Earthing

duration 30min INR 4900 INR 7000

Enquire

Description

🌐 Global Technology – One Stop Solution for Home Services in Hyderabad Global Technology is your trusted one-stop solution for all types of home services across Hyderabad and surrounding areas. We specialize in House Electrical Work, Delicate Wiring, and Generator Earthing Installation, ensuring safety, performance, and reliability for every customer. Our team of certified technicians is trained to deliver fast, clean, and professional service at your doorstep. At Global Technology, we understand how important your home’s electrical and earthing systems are for everyday comfort. Whether you need new internal wiring, delicate load management, or a complete generator earthing setup, our team handles every job with precision and care. From simple household wiring to complex grounding installations for commercial spaces, we follow industry-approved standards (ISI & IEC) to ensure your safety and system stability. Our house wiring services include main wire installation, internal circuit wiring, earthing connections, and power point fittings. We use only branded, high-quality materials such as Finolex, Polycab, and Havells cables to ensure long life and fire resistance. Every connection is double-checked, insulated, and tested before commissioning. We also offer delicate wiring for sensitive equipment like computers, CCTV cameras, home appliances, and entertainment systems β€” protecting your devices from voltage fluctuations and short circuits. The Generator Earthing Installation service by Global Technology provides robust grounding systems designed for homes, offices, and industries. Our skilled electricians install proper earth pits, copper rods, and GI strips to ensure fault current is safely discharged into the ground, preventing electric shocks, fire hazards, or damage to expensive equipment. We strictly follow IS 3043:2018 standards for earthing practices and perform resistance testing using calibrated equipment. Every service comes with a one-month service warranty, giving you peace of mind that your system is in safe hands. If any issue occurs after installation or repair, our team provides free follow-up visits within the warranty period. We believe in long-term customer relationships built on trust, transparency, and consistent quality. Our commitment to excellence has made us one of Hyderabad’s most reliable home service providers. We cater to both residential and commercial clients across areas like Madhapur, Gachibowli, Kukatpally, Miyapur, Kondapur, and all major localities. From minor repairs to complete electrical setups, no job is too small or too large for our expert team. We also offer value-added services such as plumbing, inverter installation, UPS connection, geyser fixing, CCTV installation, and decorative lighting setup, making Global Technology your complete home service partner. For fast, affordable, and professional service, contact us today: πŸ“ž Call: 7780517507 πŸ“§ Email: helpglobaltechnology2814@gmail.com πŸ’¬ Support Hours: 8 AM – 9 PM, Monday to Sunday Choose Global Technology β€” where quality, safety, and service come together. Experience reliable home solutions with professional workmanship and guaranteed satisfaction in every project.

Other Specifications

  • Other specifications : 
  • ⚑🌍 Earthing Installation – Key Specifications (All Telangana Areas) Safe | IS-Compliant | Long-Life Grounding Solutions for Electrical Systems βœ… Service Coverage – All Over Telangana: We provide complete earthing solutions across Hyderabad, Warangal, Karimnagar, Nizamabad, Mahbubnagar, Khammam, Siddipet, Zaheerabad, Medak, Nalgonda, Adilabad, and all rural/urban zones. βœ… Types of Earthing Systems Provided: GI Pipe Earthing (Galvanized Iron) Economical & durable for residential buildings Uses 2.5–3 meter GI pipe with salt/charcoal chamber Copper Plate Earthing High conductivity, suitable for sensitive equipment (UPS, data centers) Uses 600x600x3.15 mm copper plate (as per IS 3043) Chemical Earthing (Maintenance-Free) Ideal for apartments, commercial, and telecom towers With GI/Copper electrode and backfill compound (BFC) Long lifespan (10–20 years) Plate & Rod Earthing As per industrial norms using copper or GI rods For high fault current dissipation Lightning Protection Earthing Lightning arrestor ground pit setup With proper bonding and down conductor routing Transformer & Generator Earthing Double earthing system for neutral and body grounding Cable & earth busbar integration for industrial loads βœ… Materials & Components Used: Earthing Electrodes: GI/Copper rods or plates Backfill Compound: Bentonite, carbon + salt mix, or chemical gel Earth Pit Chamber: Concrete or PVC chamber with cover Copper Strip/Wire: 25x3 mm or 8–16 sq.mm for bonding Earth Busbar, Lugs & Clamps – ISI grade βœ… Standards & Compliance: Conforms to IS 3043: Code of Practice for Earthing Follows CEA Regulations & safety norms for residential, commercial, and industrial buildings Tested for resistance < 1 Ohm (for sensitive installations) βœ… Installation Process Includes: Site inspection and soil resistivity test Pit excavation and electrode placement Filling with BFC, salt, charcoal, or chemical gel Chamber capping with inspection cover Resistance testing and load system bonding Final report and maintenance guidance βœ… Resistance Testing & Certification: Megger testing for earth resistance Certificate issued for builder, DG set, or industrial compliance AMC available for regular resistance checks βœ… Price Influencers: Type of earthing system (GI, Copper, Chemical) Number of pits required Depth and soil conditions Electrode size and cable length Location logistics βœ… Common Installation Areas: Homes & Apartments Hospitals & Hotels Schools & Hostels Offices & IT Parks Factories & Industrial Plants Telecom Towers DG Sets / Transformers / UPS Units βœ… Response Time & Support: Available across Telangana within 24–48 hours Emergency installation on request Technical support with experienced electricians and earth testers
  • ⚑🌍 Earthing Installation – Key Specifications (All Hyderabad Areas) Electrical Safety | IS Standards | Reliable Grounding Solutions βœ… Service Coverage – All Areas in Hyderabad: We serve Jubilee Hills, Gachibowli, Kukatpally, Miyapur, Uppal, LB Nagar, Shamshabad, Secunderabad, Hi-Tech City, and entire GHMC region including gated communities, apartments, schools, hospitals, and industrial zones. βœ… Types of Earthing Systems Provided: Conventional Earthing GI Pipe earthing / copper pipe earthing Charcoal and salt method Chemical Earthing Copper bonded rods (14.2mm, 17.2mm, 25mm dia) Maintenance-free backfill compound (BFC) Low-resistance and long-lasting Plate Earthing Copper/galvanized iron plates (600mm x 600mm) Used in large buildings & substations Electrode Earthing Safe and efficient rod-based grounding Ideal for homes, offices, and machinery setups Advanced Lightning Protection Earthing With surge protection devices (SPD) Lightning arrestor grounding systems βœ… Key Materials Used: Copper bonded rods, pure copper rods, GI rods Backfill compound (BFC) – mineral-based, corrosion resistant Cables: Single-core copper cable (6 sq.mm to 70 sq.mm) Earth pits: RCC ring-type pit covers or plastic chamber covers Pipe clamps, earthing strip (GI or copper), funnel with cover, etc. βœ… Installation Process Includes: Site inspection and soil testing Digging bore (up to 3 meters based on soil type) Installation of electrode/rod with chemical mixture Connecting earthing wire to DB/MCC panel Earth resistance testing with digital megger Pit marking and chamber sealing βœ… Safety & Standards Followed: IS 3043: Code of Practice for Earthing IEC 60364, IEEE-80, and NBC guidelines Resistance target: Below 1 to 5 ohms depending on application Weather-proof pit enclosures with proper labelling βœ… Application Areas: Residential Buildings: Individual homes, flats, villas Commercial Spaces: Shops, clinics, schools, showrooms Industrial Plants & Factories IT Parks, Data Centers, Server Rooms Generators, UPS, Inverters, Panels Elevators & Escalators Solar system grounding βœ… Advantages of Our Earthing Systems: Low maintenance and corrosion-free Fast dissipation of fault current Prevents electric shocks and equipment damage Long life (15–25 years for chemical earthing) Resistance remains stable even in dry weather βœ… Support & Service Details: Same-day service in Hyderabad Professional electricians and grounding experts Resistance testing and digital report available AMC & periodic maintenance available on request Work completion certification available (if required)
  • 🌍⚑ Earthing Installation – Key Specifications (Gachibowli, Hyderabad) Safe Grounding | IS-Compliant | Residential & Commercial Electrical Safety Solutions βœ… Service Coverage – Gachibowli Area: Full coverage in and around Gachibowli, including Financial District, DLF, Nanakramguda, TNGOs Colony, Kondapur, Kothaguda, Hitech City Extension, and gated communities like My Home Vihanga, Aparna Sarovar, L&T Serene County, etc. βœ… Types of Earthing Services Offered: Residential Earthing Installation Independent villas and apartments Earth pit setup for inverter, geyser, ACs, etc. Commercial & Office Earthing Earthing for UPS systems, server rooms, and panels Surge protection for sensitive equipment Industrial Earthing Machine and DG set earthing Lightning arrestor grounding Transformer and control panel earthing Advanced Earthing Maintenance-free earthing systems Chemical earthing and GI pipe earthing Copper-bonded and plate earthing systems βœ… Material Specifications: GI Pipe Earthing: 40mm dia, 2–3 meter length Copper Plate Earthing: 600mm x 600mm x 3mm Chemical Earthing Rods: Copper-bonded rods (14.2mm – 17.2mm) Backfill Compound: Carbon-based & Bentonite powder Earth Pit Chamber: Concrete or PVC cover with inspection hole Earthing Strip: GI or copper strip 25x3mm or 50x6mm βœ… Earthing Resistance Target: Residential: < 5 Ohms Commercial & IT: < 2 Ohms Server/Data Rooms: < 1 Ohm (with dual redundant pits) βœ… Installation Method: Site survey and soil resistivity check Bore digging (up to 3 meters) Electrode placement and compaction Use of backfill compound for low resistance Chamber installation and grounding connection Final testing using Earth Resistance Meter βœ… Testing & Compliance: Conforms to IS 3043: Code of Practice for Earthing Earth resistance testing with report Periodic maintenance & recharging available Lightning Protection System (LPS) support if required βœ… Technician Expertise: Certified electricians and earthing experts Background-verified and insured team Site safety gear used (gloves, boots, helmets)
  • 🌍⚑ Earthing Installation Services – Key Specifications (Moinabad, Telangana) Safe | Reliable | Long-Lasting Earthing Systems for All Properties βœ… Service Coverage in Moinabad Area: Full coverage of Moinabad Mandal, including Himayatnagar, Kokapet, Narsingi, Kollur, Kanakamamidi, Shankarpally Road, farmhouses, open plots, and residential layouts. βœ… Types of Earthing Installations Offered: Residential Earthing: For houses, villas, apartments Supports electrical panels, inverter, geysers, and home appliances Commercial Earthing: Offices, shops, schools, clinics Ensures protection for 3-phase systems, AC units, UPS, and elevators Industrial Earthing: Factories, warehouses, generator rooms Transformer, panel board, and machine earthing Farm & Borewell Earthing: For motors, pumps, solar fencing, borewells Ideal for agricultural lands and farmhouses Lightning Arrester Earthing: Complete installation with earth pit Lightning protection for tall buildings and open structures βœ… Earthing Types & Material Options: Pipe Type Earthing GI pipe (2.5m/3m) with charcoal & salt Economical & widely used Plate Type Earthing GI or Copper Plate (600mm x 600mm x 6mm/3mm) Best for commercial/industrial use Chemical Earthing GI/Copper electrode with backfill compound Maintenance-free, long life, ideal for harsh soils Copper Bonded Rod Earthing 17mm/25mm copper bonded rods with bentonite backfill Corrosion-resistant, low resistance βœ… Materials Used (Branded & ISI-Approved): Copper/GI Rods, backfill compounds Charcoal, salt, earth enhancement chemicals Earth pit covers, watering funnel, clamps Earthing strips (25x3, 50x6 mm) as per load βœ… Installation Process: Site inspection and soil resistivity check Pit digging (depth as per terrain, usually 6–10 ft) Electrode positioning and backfilling Watering system and pit cover fixing Resistance testing using Earth Megger Final report with readings if required βœ… Safety & Compliance: As per IS 3043: Code of Practice for Earthing Ensures protection against shock, lightning, overloads Follows electrical safety rules for residential & industrial connections βœ… Earthing Resistance Goals: Residential: Below 5 Ohms Commercial: Below 2–3 Ohms Lightning Protection: < 1 Ohm βœ… Why Choose Our Service in Moinabad: Trained electricians and technicians On-site inspection & resistance testing Materials with warranty & certification Quick turnaround (Same-day or next-day installation) Suitable for new buildings, upgrades & maintenance
  • Home earthing, also known as grounding, is a crucial safety measure that protects your home and appliances from electrical faults. Here's a breakdown of the key specifications for a proper home earthing system:1. Earthing Electrode: * Type: Common types include: * Rod Electrode: A copper or galvanized iron rod driven vertically into the ground. This is the most common type. * Plate Electrode: A copper or galvanized iron plate buried horizontally in the ground. Less common now due to the larger area needed. * Strip Electrode: A copper or galvanized iron strip buried horizontally in a trench. Used where driving a rod is difficult. * Material: Copper is the best conductor and most corrosion-resistant, but galvanized iron is a more economical option. Aluminum is sometimes used but is less common due to corrosion concerns in some soils. * Dimensions: The dimensions depend on the type of electrode and soil resistivity. Generally: * Rod: A copper rod should be at least 2 meters long and 12.5mm in diameter. Galvanized iron rods should be at least 2 meters long and 20mm in diameter. * Plate: A copper plate should be at least 600mm x 600mm x 3mm. A galvanized iron plate should be at least 600mm x 600mm x 6mm. * Strip: A copper strip should be at least 25mm x 4mm. A galvanized iron strip should be at least 32mm x 5mm. * Depth: The electrode should be installed deep enough to reach moist soil, as this improves conductivity. The top of the rod or plate should be at least 50cm below ground level.2. Earth Wire (Connecting Wire): * Material: Copper is preferred for its conductivity and corrosion resistance. Galvanized steel is sometimes used for cost reasons, but copper is highly recommended. * Size: The size of the earth wire depends on the size of the circuit it's protecting. It should be large enough to carry the fault current without overheating. Consult local electrical codes for specific requirements. Generally, it should be no less than 4mmΒ² copper. * Insulation: The earth wire must be insulated to prevent accidental contact. Green insulation is the standard color for earth wires.3. Earth Pit: * Construction: The earth pit is a small enclosure around the earth electrode, usually made of brick or concrete. It allows access to the electrode for testing and maintenance. * Cover: The pit should have a cover to prevent accidental falls and keep out debris.4. Testing and Maintenance: * Regular Testing: The earth resistance should be tested periodically (at least once a year) by a qualified electrician. A low earth resistance is crucial for effective protection. * Watering: In dry areas, it may be necessary to periodically water the earth pit to maintain moisture levels and ensure good conductivity.5. Local Electrical Codes and Regulations: * Compliance: Earthing systems must comply with local electrical codes and regulations. These codes specify the requirements for materials, dimensions, installation methods, and testing. It is ESSENTIAL to consult these local regulations. In India, the relevant standard is IS 3043.Key Considerations: * Soil Resistivity: The type of soil significantly impacts the effectiveness of the earthing system. High resistivity soil requires larger electrodes or more complex earthing arrangements. A soil resistivity test is advisable. * Number of Earth Pits: Multiple earth pits may be required for larger installations or areas with high soil resistivity. They should be interconnected. * Professional Installation: It's highly recommended to have a qualified electrician design and install the earthing system. This ensures compliance with codes and proper functioning.A properly installed earthing system is essential for the safety of your home and family. Don't take shortcuts with this critical safety feature. Always consult with a qualified electrician.
Book Appointment

No services available for booking.

Select Staff

AnyBody

Morning
    Afternoon
      Evening
        Night
          Appointment Slot Unavailable
          Your enquiry
          Mobile or Email

          Appointment date & time

          Sunday, 7 Aug, 6:00 PM

          Your Name
          Mobile Number
          Email Id
          Message

          Balinese massage - 60 min

          INR 200

          INR 500

          services True True +918048061672